Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Braz. j. oral sci ; 22: e238152, Jan.-Dec. 2023. ilus
Artigo em Inglês | LILACS, BBO | ID: biblio-1437694

RESUMO

Aim: This study evaluated the influence of a wide diameter on extra-short dental implant stress distribution as a retainer for single implant-supported crowns in the atrophic mandible posterior region under axial and oblique load. Methods: Four 3D digital casts of an atrophic mandible, with a single implant-retained crown with a 3:1 crown-to-implant ratio, were created for finite element analysis. The implant diameter used was either 4 mm (regular) or 6 mm (wide), both with 5 mm length. A 200 N axial or 30º oblique load was applied to the mandibular right first molar occlusal surface. The equivalent von Mises stress was recorded for the abutment and implant, minimum principal stress, and maximum shear stress for cortical and cancellous bone. Results: Oblique load increased the stress in all components when compared to axial load. Wide diameter implants showed a decrease of von Mises stress around 40% in both load directions at the implant, and an increase of at least 3.6% at the abutment. Wide diameter implants exhibited better results for cancellous bone in both angulations. However, in the cortical bone, the minimum principal stress was at least 66% greater for wide than regular diameter implants, and the maximum shear stress was more than 100% greater. Conclusion: Extra-short dental implants with wide diameter result in better biomechanical behavior for the implant, but the implications of a potential risk of overloading the cortical bone and bone loss over time, mainly under oblique load, should be investigated


Assuntos
Implantes Dentários , Arcada Parcialmente Edêntula , Prótese Dentária Fixada por Implante , Análise de Elementos Finitos
2.
Braz. oral res. (Online) ; 36: e081, 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO | ID: biblio-1394172

RESUMO

Abstract This longitudinal study aimed to assess the performance of the Facility-Equator system as mandibular overdenture (MO) retainers from a prosthetic perspective during 2 years of loading and to investigate the oral health-related quality of life (OHRQoL) and whether prosthetic events can affect the OHRQoL. Twenty-four patients (68.1 ± 7.51 years) reported their OHRQoL through the Geriatric Oral Health Assessment Index (GOHAI) and Oral Health Impact Profile (OHIP-EDENT) questionnaires before MO loading and after 1 and 2 years of usage. Prosthetic occurrences were recorded during this period. Data were analyzed using the Wilcoxon test, Mann-Whitney test, and Spearman correlation coefficients. Of the 127 prosthetic events that occurred in the first year, the most frequent events were prosthesis adjustments (16.5%), dislodgement of the Equator attachment (14.17%), and O-ring replacement (11.8%). Eighty-seven prosthetic events were recorded in the second year, the most frequent events being prosthesis adjustments (27.6%), O-ring replacement (20.7%), and recapturing the female matrix (11.5%). All domains of the GOHAI and OHIP-EDENT questionnaires exhibited a significant difference (p < 0.05) between the baseline and 1- and 2-year evaluations, except in the Social Disability and Psychological Discomfort domains (p > 0.05) of OHIP-EDENT after 1 year. Complications related to prosthetic maintenance, such as fracturing of the prosthesis, Equator dislodgement, prosthesis rebasing, and new overdenture confection, affect the OHRQoL (p < 0.05), primarily the Physical Pain and Discomfort domains, especially in the first year of MO loading.

3.
Braz. j. oral sci ; 20: e214873, jan.-dez. 2021. ilus
Artigo em Inglês | BBO, LILACS | ID: biblio-1254742

RESUMO

Aim: To compare the marginal fit of lithium disilicate CAD/CAM crowns and heat-pressed crowns fabricated using milled wax patterns, and evaluate its effect on stress distribution in implantsupported rehabilitation. Methods: A CAD model of a mandibular first molar was designed, and 16 lithium disilicate crowns (8/group) were obtained. The crown-prosthetic abutment set was evaluated in a scanning electron microscopy. The mean misfit for each group was recorded and evaluated using Student's t-test. For in silico analysis, a virtual cement thickness was designed for the two misfit values found previously, and the CAD model was assembled on an implant-abutment set. A load of 100 N was applied at 30° on the central fossa, and the equivalent stress was calculated for the crown, titanium components, bone, and resin cement layer. Results: The CAD/CAM group presented a significantly (p=0.0068) higher misfit (64.99±18.73 µm) than the heat-pressed group (37.64±15.66 µm). In silico results showed that the heat-pressed group presented a decrease in stress concentration of 61% in the crown and 21% in the cement. In addition, a decrease of 14.5% and an increase of 7.8% in the stress for the prosthetic abutment and implant, respectively, was recorded. For the cortical and cancellous bone, a slight increase in stress occurred with an increase in the cement layer thickness of 5.9% and 5.7%, respectively. Conclusion: The milling of wax patterns for subsequent inclusion and obtaining heat-pressed crowns is an option to obtain restorations with an excellent marginal fit and better stress distribution throughout the implant-abutment set


Assuntos
Microscopia Eletrônica de Varredura , Desenho Assistido por Computador , Adaptação Marginal Dentária , Prótese Dentária Fixada por Implante , Análise de Elementos Finitos , Materiais Dentários
4.
Braz. oral res. (Online) ; 34: e113, 2020. tab, graf
Artigo em Inglês | LILACS, BBO | ID: biblio-1132680

RESUMO

Abstract Here, the prevalence of oral candidiasis and denture stomatitis among diabetic patients compared to healthy ones was summarized through a systematic review with meta-analysis. Medline, Scopus, Web of Science, Lilacs, Cochrane Library, Embase, and the grey literature were searched without restriction, until May 2020. Eligibility criteria were established, data were extracted, and quality assessment was conducted by two trained examiners. Qualitative synthesis was based on the recommendations of Fowkes and Fulton. Two meta-analyses were performed on studies investigating patients with: a) oral candidiasis and b) denture stomatitis. Out of 6034 screened studies, seven were eligible for qualitative and quantitative synthesis; of these, three evaluated oral candidiasis and four evaluated denture stomatitis. Qualitative synthesis showed that the main methodological problems of the studies included sample size, source of controls, matching, and randomization. Diabetic patients had a similar chance of developing oral candidiasis to non-diabetic patients (OR1.40 [0.96; 2.04], p = 0.08, I2 = 94%). However, diabetic patients had a higher chance to present denture stomatitis compared to non-diabetic patients (OR 1.92 [1.42, 2.59] p < 0.0001, I2 = 0%). Therefore, diabetic patients have a higher chance of developing denture stomatitis compared to non-diabetic patients. However, for all analyses, the certainty of the evidence was considered to be very low.


Assuntos
Humanos , Estomatite sob Prótese/epidemiologia , Candidíase Bucal/epidemiologia , Diabetes Mellitus/epidemiologia
5.
Braz. oral res. (Online) ; 32: e110, 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-974439

RESUMO

Abstract This randomized clinical trial evaluated the insertion torque (IT), primary, and secondary stability of dental implants with different surface treatments during the osseointegration period. Nineteen patients with bilateral partial edentulism in the posterior mandibular region were randomly allocated to two implant brand groups and received implants with different surface treatments in the opposite site of the arch: Osseotite and Nanotite or SLA and SLActive. During implant placement, the maximum IT was recorded using a surgical motor equipped with a graphical user interface. The implant stability quotient (ISQ) was assessed immediately after the IT, and was measured weekly via resonance frequency analysis during 3 months. The data were analyzed by a one-way ANOVA, the Bonferroni test, paired t tests and Pearson's correlation coefficient. The IT values were similar (p > 0.05) for all implant types ranging from 43.82 ± 6.50 to 46.84 ± 5.06. All implant types behaved similarly until the 28th day (p > 0.05). Between 35 and 56 days, Osseotite and SLActive showed lower ISQ values (p < 0.001) compared to Nanotite and SLA implants. After 56 days, only Osseotite maintained significantly lower ISQ values than the other implants (p < 0.05). After 91 days the ISQ values were significantly higher than the baseline for all four implant types (p < 0.001). The ISQ and IT values were significantly correlated at the baseline and at the final evaluation for Osseotite, Nanotite, and SLActive implants (p < 0.001). After 91 days, ISQ and IT values were only significantly correlated for the Osseotite implants (p < 0.05). All implants types exhibited acceptable primary and secondary stability.


Assuntos
Humanos , Masculino , Feminino , Implantes Dentários/normas , Osseointegração/fisiologia , Implantação Dentária Endóssea/métodos , Valores de Referência , Propriedades de Superfície , Fatores de Tempo , Radiografia , Análise de Variância , Resultado do Tratamento , Planejamento de Prótese Dentária , Torque , Pessoa de Meia-Idade
6.
Braz. oral res. (Online) ; 31: e5, 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-839513

RESUMO

Abstract The aim of this longitudinal observational study was to evaluate the oral health-related quality of life (OHRQoL) following patient rehabilitation with implant-retained mandibular overdentures (IMO) and to identify the contribution of the different domains to OHRQoL. The Oral Health Impact Profile (OHIP-EDENT), Dental Impact on Daily Living (DIDL), and Geriatric Oral Health Assessment Index (GOHAI) questionnaires were completed twice by 25 patients: after 3 months of rehabilitation with complete dentures (CD) and after 3 months of IMO loading using stud abutments. The evaluation after IMO rehabilitation showed significant improvement in three DIDL domains: appearance (p = 0.011), eating and chewing (p = 0.003), and general performance (p = 0.003). The GOHAI results showed significant differences in two domains: psychosocial (p = 0.005) and pain and discomfort (p = 0.0004). The OHIP-EDENT outcomes showed significant improvements in five domains: functional limitation (p = 0.0001), physical pain (p = 0.0002), physical disability (p = 0.0010), and psychological disability and handicap (p = 0.032). The largest observed effect sizes were close to one standard deviation and were observed in the eating and chewing domain (0.93) of the DIDL; the pain and discomfort domain (0.83) of the GOHAI, and the functional limitation (0.89), physical pain (1.02), physical disability (0.84) domains of the OHIP-EDENT. The percentage of satisfied patients increased in all domains. Self-reported OHRQoL of CD wearers was significantly improved after 3 months of treatment with IMO, especially concerning the functional and pain-related aspects.


Assuntos
Humanos , Masculino , Feminino , Idoso , Qualidade de Vida , Implantes Dentários , Saúde Bucal , Prótese Mandibular , Autoimagem , Dor Facial/fisiopatologia , Atividades Cotidianas , Estudos Longitudinais , Satisfação do Paciente , Estatísticas não Paramétricas , Revestimento de Dentadura , Revestimento de Dentadura/psicologia , Avaliação da Deficiência , Autorrelato , Prótese Mandibular/psicologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA